• <style id="kcfgx"><mark id="kcfgx"></mark></style>

      Welcome to the website of Baoji Zhongheng Instrument Co., Ltd. Tel:+86-917-3512881
      Differential pressure transmitter Single crystal silicon pressure transmitter Electromagnetic flowmeter Capacitive pressure transmitter High precision pressure transmitter Intelligent pressure switch Diffused silicon pressure transmitter Flow switch Intelligent pressure transfer controller Thermometer

      Liquid level transmitter


      BXY6001 Differential Pressure

      Product code

       

      Overview

      Product quotationProduct consulting

      Product introduction

      The thermal flow switch adopts precision electronic components widely used in aviation and automobiles, and its reliable and stable circuit design makes the flow signal more accurate and stable. Currently, it has been widely used in industries such as steel, metallurgy, pharmaceuticals, and chemical engineering
      The ZH-L2 thermal flow switch is an upgraded version of the ZH-L1 model, which not only has more prominent improvements in the signal processing of the flow switch probe, but also makes the HL-L2 software operation and control functions more powerful; Easy to operate and easy to install.

      The measuring principle of the ZH-L2 thermal flow switch is the same as that of the ZH-L1, and it is also designed based on the principle of heat exchange. The probe is equipped with a heating module and a heat sensing module, and the heat dissipation of the heating module is closely related to the flow rate of the measured fluid. If there is no medium flow in the pipeline, the signal received by the heat sensing circuit is a fixed value; When the fluid medium flows through the probe, the signal received by the thermal circuit changes with the flow rate of the medium. The thermal circuit converts the temperature difference signal between the heating module and the thermal module into an electrical signal, and the processor then converts it into signals such as PNP/NPN/4-20mA/relay for output.
      Gas liquid dual purpose, can be used for gas and hydraulic systems, circulating water, cutting fluid and lubricating oil cutoff monitoring, and pump idle protection.

      Range code


      minimum range

      maximum range

      Rated pressure (maximum)

      B

      1kPa

      6kPa

      Rated pressure of liquid level flange

      C

      4kPa

      40kPa

      D

      25kPa

      250kPa

      E

      200kPa

      2MPa

      Table 2 Comparison Table of the Relationship between Liquid Level Flange and Minimum Range

      Level flange

      Nominal diameter

      minimum range

      Flat type

      DN 50/2”

      10kPa

      DN 80/3”

      1kPa

      DN 4”

      1kPa

      plug-in

      DN 50/2”

      16kPa

      DN 80/2”

      1kPa

      DN 4”

      1kPa

      The minimum range of the differential pressure liquid level transmitter should be the larger value of the minimum range in Table 1 and Table 2. The adjusted range shall not be less than the minimum range. The maximum range of the liquid level transmitter should be the minimum of the maximum range of the transmitter body and the rated pressure of the liquid level flange.
      4 output signals
      2-wire system, 4-20mADC HART output, digital communication, with HART protocol loaded on 4-20mADC signal.
      Output signal limit: Imin=3.9mA, Imax=20.mA
      Alarm current (mode can be set)
      Low alarm mode (minimum): 3.7 mA
      High alarm mode (maximum): 21 mA
      No alarm mode (hold): maintain the effective current value before the fault
      Alarm current standard setting: high alarm mode
      5 Response time
      The damping constant of the amplifier component is 0.1s; The time constant of the sensor and liquid level flange is 0.2-2 seconds, depending on the range and range ratio. The additional adjustable time constant is 0.1~60s.
      6 General conditions
      6.1 Installation conditions
      The liquid level flange transmitter can be directly fixed in any position. The optimal state is to keep the process flange axis in a vertical position, and the positional deviation will result in a correctable zero offset. The electronic watch case can rotate up to 360 °, and the positioning screw can fix it in any position.
      6.2 Environmental conditions
      ambient temperature
      Minimum: depending on the filling fluid
      Maximum: 85 ℃
      When equipped with LCD display and fluororubber sealing ring, -20~65 ℃
      Storage temperature/transportation temperature
      Minimum: depending on the filling fluid
      Maximum: 85 ℃
      Relative humidity
      0-100%
      Impact resistance
      Acceleration: 50g
      Duration: 11ms
      Anti vibration
      2g to 500Hz
      Electromagnetic compatibility (EMC)
      See Table 3 "Electromagnetic Compatibility Schedule" on the next page
      6.3 Process Medium Limits
      Medium temperature limit: -30~180 ℃
      Transmitter body pressure limit
      From an absolute pressure of 3.5kPa to the rated pressure, the protective pressure can be greater than 1.5 times the rated pressure and applied to both sides of the transmitter.
      Rated pressure of liquid level flange
      ANSI standard: 150psi~600psi
      DIN standard: PN 1.6MPa~PN 10MPa
      Unidirectional overload limit
      The low pressure side is the rated pressure of the transmitter body, and the high pressure side is the rated pressure of the liquid level flange, which may cause adjustable zero drift.
      Weight: DN 50/2 "approximately 7-10kg; DN 80/3 "approximately 8-11kg; DN 4 "is approximately 9-12kg.
      Explosion proof performance
      NEPSI Flameproof License: Ex d Ⅱ C T6
      NEPSI Intrinsic Safety License: Ex ia IIC T4
      Permissible operating temperature: -40 ℃~65 ℃
      6.4 Power supply and load conditions
      The power supply voltage is 24V
      R ≤ (Us-12V)/Imax k Ω
      Where Imax=23 mA
      Maximum power supply voltage: 42VDC
      Minimum power supply voltage


      Serial Number

      Test items

      Basic standards

      Test conditions

      Performance Level

      1

      Radiated interference (shell)

      GB/T 9254-2008表5

      30MHz~1000MHz

      qualified

      2

      Conducted interference
      (DC power port)


      GB/T 9254-2008表1

      0.15MHz~30MHz

      qualified

      3

      Electrostatic discharge (ESD) immunity

      GB/T 17626.2-2006

      4kV(觸點)

      8kV(空氣)

      B

      4

      Radio frequency electromagnetic field immunity

      GB/T 17626.3-2006

      10V/m (80MHz~1GHz)

      A

      5

      Power frequency magnetic field immunity

      GB/T 17626.8-2006

      30A/m

      A

      6

      Electrical fast transient pulse group immunity

      GB/T 17626.4-2008

      2kV(5/50ns,5kHz)

      B

      7

      Surge immunity

      GB/T 17626.5-2008

      1kV(Between lines)

      2kV(Between lines)(1.2us/50us)

      B

      8

      Immunity to conducted interference induced by radio frequency fields

      GB/T 17626.6-2008

      3V (150KHz~80MHz)

      A

      Note: (1) A performance level description: During testing, the performance is normal within the technical specification limits.
      (2) B performance level description: During testing, the function or performance is temporarily reduced or lost, but it can recover on its own, and the actual operating status, storage, and data remain unchanged.
      External dimension unit (mm)


      Table 4 Structural dimensions of liquid level flange

      Nominal diameter

      Rated pressure

      ΦD

      ΦK

      Φd1

      Φd2

      Φd3

      t

      b

      Required bolts

      plug-in

      Flat type

      number

      thread

      DN 50

      PN1.6/4MPa

      165

      125

      48.3

      57

      102

      3+0.5

      20

      4

      M16

      (Sealing surfaceDIN 2526E

      PN 6.4MPa

      18

      135

      48.3

      57

      102

      3+0.5

      26

      4

      M20

      (flangeDIN 2501)

      PN 10MPa

      195

      145

      48.3

      57

      102

      3+0.5

      28

      4

      M20

      DN 80

      PN1.6/4MPa

      200

      160

      76

      75

      138

      3+0.5

      24

      8

      M16

      (Sealing surface DIN 2526E type)

      PN 6.4MPa

      215

      170

      76

      75

      138

      3+0.5

      28

      8

      M20

      (Flange DIN 2501)

      PN 10MPa

      230

      180

      76

      75

      138

      3+0.5

      32

      8

      M24

      DN 2"
      (ANSI B 16.5 RF)

      150psi

      152.4

      120.6

      48.3

      57

      92.1

      3+0.5

      17.4

      4

      M18

      300psi

      165.1

      127.0

      48.3

      57

      92.1

      3+0.5

      20.6

      8

      M18

      600psi

      165.1

      127.0

      48.3

      57

      92.1

      6.35

      31.75

      8

      M18

      DN 3"
      (ANSI B 16.5 RF)

      150psi

      190.5

      152.4

      76

      75

      127

      3+0.5

      22.2

      4

      M16

      300psi

      209.5

      168.3

      76

      75

      127

      3+0.5

      27.0

      8

      M20

      600psi

      209.5

      168.3

      76

      75

      127

      6.35

      38.05

      8

      M20

      DN 4“

      150psi

      229

      191

      89

      89

      157

      3+0.5

      30

      8

      M18

      (ANSI B 16.5 RF)

      300psi

      255

      200

      89

      89

      157

      3+0.5

      32

      8

      M18

      Note: Users can choose to install bolts and nuts.
      7 Electrical connection diagram


      Note: The quick interface function is equivalent to the signal terminal.
      8. Instructions for Low Voltage End Process Connection










      ?