      Differential pressure transmitter Single crystal silicon pressure transmitter Electromagnetic flowmeter Capacitive pressure transmitter High precision pressure transmitter Intelligent pressure switch Diffused silicon pressure transmitter Flow switch Intelligent pressure transfer controller Thermometer

      Pressure transmitter


      BXY6012/13- Differential Press

      Product code

       

      Overview

      Product quotationProduct consulting

      Product introduction

      BXY6012 Differential Pressure Installation Gauge
      transmitter
      BXY6013- Differential pressure installation absolute pressure
      transmitter
      BXY6012/3-Differential pressure mounted gauge/absolute pressure transmitter is used to measure the liquid level, density, and pressure of liquids, gases, or vapors, and then convert it into a 4-20mADC HART current signal output. BXY6012/3 can also communicate with RST375 handheld terminals or RSM100 Modems for parameter setting, process monitoring, etc.
      Standard specifications
      (Calibrate the range based on the standard zero point, stainless steel 316L diaphragm, filled with silicone oil)
      1 Performance specifications
      Reference accuracy for range adjustment
      (Including linearity, backlash, and repeatability from zero)
      ± 0.075%
      If TD>10 (TD=maximum range/adjustment range), then it is:
      ± (0.0075 × TD)%
      Environmental temperature impact


      Range code

      -20℃~65℃Total impact amount

      B/L

      ±(0.30×TD+0.20)%×Span

      other

      ±(0.20×TD+0.10)%×Span

      Range code

      -40℃~-20℃和65℃~85℃Total impact amount

      B/L

      ±(0.30×TD+0.20)%×Span

      other

      ±(0.20×TD+0.10)%×Span


      Overrange impact:±0.075%×Span


      Long term stability

      Range code

      influence quantity

      B/L

      ±0.2%×Span/1year

      other

      ±0.1%×Span/1year


      Power impact
      ± 0.001%/10V (12-42V DC), negligible
      2 Functional specifications
      Range and range (BXY6012 gauge pressure transmitter)


      Range/Range

      kPa

      bar

      B

      Range

      0.6~6

      6~60mbar

      Range

      -6~6

      -60~60mbar

      C

      Range

      2~40

      0.02~0.4

      Range

      -40~40

      -0.4~0.4

      D

      Range

      2.5~250

      0.025~2.5

      Range

      -100~250

      -1~2.5

      F

      Range

      30~3000

      0.3~30

      Range

      -100~3000

      -1~30

      G

      Range

      0.1~10MPa

      1~100

      Range

      -0.1~10MPa

      -1~100

      H

      Range

      0.21~21 MPa

      2.1~210

      Range

      -0.1~21 MPa

      -1~210

      I

      Range

      0.4~40 MPa

      4~400

      Range

      -0.1~40 MPa

      -1~400


      Range and Range (BXY6013 Absolute Pressure Transmitter)

      Range and Range

      kPa

      bar

      L

      Range

      2~40

      0.02~0.4

      Range

      0~40

      0~0.4

      M

      Range

      2.5~250

      0.025~2.5

      Range

      0~250

      0~2.5

      O

      Range

      30~3000

      0.3~30

      Range

      0~3000

      0~30


      Range limit
      Within the upper and lower limits of the range, it can be adjusted arbitrarily. It is recommended to select range codes with the lowest possible range ratio to optimize performance characteristics.
      Zero point setting
      The zero point and range can be adjusted to any value within the measurement range in the table, as long as the calibrated range is ≥ the minimum range
      Installation position impact
      The change in installation position parallel to the film surface will not cause zero drift effect. If the change in installation position exceeds 90 ° with the film surface and there is a zero position effect within the range of<0.4kPa, it can be corrected by adjusting zero. No range impact.
      output
      2-wire system, 4-20mADC, selectable for digital communication with HART output, with options for linear or square root output.
      Output signal limit: Imin=3.9mA, Imax=20.mA
      Alarm current
      Low alarm mode (minimum): 3.7 mA
      High alarm mode (maximum): 21 mA
      No alarm mode (hold): maintain the effective current value before the fault
      Alarm current standard setting: high alarm mode
      response time
      The damping constant of the amplifier component is 0.1s; The sensor time constant is between 0.1 and 1.6 seconds, depending on the range and range ratio. The additional adjustable time constant is 0.1~60s.
      Preheating time:<15s
      ambient temperature
      -40-85 ℃
      When equipped with LCD display and fluororubber sealing ring, -20~65 ℃
      Storage temperature/transportation temperature
      -50-85 ℃
      With LCD display: -40~85 ℃
      Pressure limit: from vacuum to maximum range.
      Overload limit:


      range

      6kPa

      (1B)

      40kPa

      (1C/1L)

      250kPa

      (1D/1M)

      Overload limit

      16MPa

      16MPa

      16MPa

      range

      2(3)MPa

      (1E/1O)

      10MPa

      (1G)

      21MPa

      (1H)

      40MPa

      (1I)

      Overload limit

      16MPa

      20MPa

      25MPa

      45MPa


      Electromagnetic compatibility (EMC): see "Electromagnetic Compatibility Schedule" on the next page
      3 Installation
      Power supply and load conditions
      The power supply voltage is 24V, R ≤ (Us-12V)/Imax k Ω
      Where Imax=23 mA
      Maximum power supply voltage: 42VDC
      Minimum power supply voltage: 12VDC, 15VDC (backlight LCD display)
      Digital communication load range: 230~600 Ω
      Electrical connections
      M20X1.5 cable sealing buckle and wiring terminal are suitable for wires ranging from 0.5 to 2.5mm2.
      Process Connection
      The end face of the process connection flange has NPT 1/4 and UNF 7/16 internal threads.
      4 Physical specifications
      material quality
      Diaphragm: stainless steel 316L, Hastelloy C
      Process connection: stainless steel 316L
      Filling fluid: silicone oil
      Transmitter housing: aluminum alloy material, with epoxy resin sprayed on the surface
      Shell sealing ring: nitrile rubber (NBR)
      Nameplate: stainless steel 304
      weight
      3.3kg (without LCD display, mounting bracket, process connection)
      Shell protection level: IP67
      Electromagnetic Compatibility Schedule

      (1) A performance level description: During testing, the performance was normal within the technical specification limits.
      (2) B performance level description: During testing, the function or performance is temporarily reduced or lost, but it can recover on its own, and the actual operating status, storage, and data remain unchanged.
      External dimension unit (mm)

      Wall mounted connection method Vertical piping connection method


      5 Electrical connection diagram



      Note: The quick interface function is equivalent to the signal terminal.
      6 Process Connection Instructions











      ?
      久久大香香蕉国产,亚洲最大在线无码片,精品国精品国产自在久久,尤物萝控精品福利视频的 亚洲96在线观看 亚洲精品91福利在线观看